| Indoor units without DHW tank
| HOP60W IDU
| HOP100W IDU
| HOP100W IDU3
| HOP160W IDU3
|
| Compatible outdoor models |
HOP6W ODU |
HOP8W ODU |
HOP10W ODU |
HOP8W ODU |
HOP10W ODU |
HOP12W ODU3 |
HOP16W ODU3 |
| Built-in electric heater |
kW |
3 |
9 (3+3+3) |
| Power supply |
V/Ph/Hz |
220-240/1/50 |
380-415/3/50 |
| Rated power |
W |
3095 |
9095 |
| Rated current |
A |
13,5 |
13,3 |
| Power cable |
mm2 |
3×2,5 |
5×2,5 |
| Communication cable, AWG18 shielded |
mm2 |
2×0,75 |
| Automatic switch |
A |
C16 |
C16~3 |
| Sound power level |
dB(A) |
38 |
42 |
43 |
| Sound pressure |
dB(A) |
28 |
30 |
32 |
| Dimension (W x H x D) |
mm |
420x790x270 |
| Dimension of Package (W x H x D) |
mm |
525x1050x360 |
| Circulation Pump |
Type |
DC, electronic |
| Maximum lifting height |
m |
9 |
| Power |
W |
5~90 |
| Minimum water flow |
m3/h |
0,36 |
0,6 |
| Operating limits for water flow |
m3/h |
0,4 ~ 1,25 |
0,4 ~ 2,1 |
0,7 ~ 3,0 |
| Heat exchanger |
Plate, soldered |
| Expansion tank |
l |
8 |
| Refrigerant pipes |
Liquid phase |
mm (col) |
6,35 (1/4”) |
9,52 (3/8”) |
| Gas phase |
mm (col) |
15,88 (5/8”) |
| Water pipe connection |
R1” |
| Net / Gross weight |
kg |
43 / 49 |
45 / 51 |
| Supply water temperature |
Heating |
°C |
+12 ~ +65 |
| Cooling |
°C |
+5 ~ +30 |
| DHW |
°C |
+12 ~ +60 |
| Ambient temperature |
°C |
0 ~ +35 |
| Water pressure in the system |
bar |
1 ~ 3 |