Electrolux Heat Pumps

Add to Wishlist
Add to Wishlist

Heat pumps air-water

Heat pumps «air-water» are created to use energy of air to heat water. They are efficient solution for significant consumption locations – private houses, small restaurants, shops and offices. Innovative technologies are integrated into a reliable, economical, multifunctional system for hot water supply (HWS), air conditioning, radiator and underfloor heating.

Add to Wishlist
Add to Wishlist
Category:

Online payment option

Description

Heat pumps air-water

Heat pumps «air-water» are created to use energy of air to heat water. They are efficient solution for significant consumption locations – private houses, small restaurants, shops and offices. Innovative technologies are integrated into a reliable, economical, multifunctional system for hot water supply (HWS), air conditioning, radiator and underfloor heating.

Technical privilege of EHB-EMHP heat pump system is constructed to deliver exceptional energy efficiency. The appliance is ready to pump 3-5 kW of heat at the cost of 1 kW, which confirms efficiency class А+++ and means more than 500% of value in everyday practice. 

 

 

For even more comfort and safety experience the following features: 

 

  • Simple touch control

    Intuitive LCD-screen with self-diagnostics of operational parameters, error codes display and child lock system. 

  • Wide operation range

    The heat pump system is effective from -25°C to +35°C outdoors for heating and from -5°C to +46°C outdoors for cooling. It is capable to heat water up to +65°C. 

  • Really quiet work

    This factor is important when the device is on non-stop, day and night. Reliable and smart designed details: low noise inverter pumps and optimized hydraulic circuit – in-house sound from 38 to 43 dB(A), which is compared to the rustle of trees or bird’s wings. 

  • Daily and weekly schedule

    Schedule features (daily and weekly) make it easier to manage the device. The two period schedules cannot be synchronized and are used separately. Up to 6 events can be set within daily schedule. 

  • Automatic temperature switch

    Modern weather-dependent automation switches water degree when the outdoor air degree increases or decreases. This is done for rapid weather adaptation and maintenance of optimal ratio between the indoor and outdoor temperature. There are 32 fixed and 1 individual weather and temperature set points. 

  • Power limit feature

    The heat pump system may be used with various power sources. Eight different power levels are available in menu. Selection procedure is simple and requires a short setup using the wired remote control. 

  • Holiday away mode

    To avoid freezing in cold climate or season, improve system reliability and save energy – the Holiday away mode is activated when leave. It might be heating mode and / or HWS mode – maintaining water temperature stable low but non-freezing.

Model name EMHP-  EMHP-8V/N8 EECEMHP-10V/N8 EECEMHP-12V/N8 EECEMHP-14V/N8 EECEMHP-16V/N8 EEC
Compatible hydronic box EHB-EHB-100/N8 EECEHB-160/N8 EEC
Power supplyV/Ph/Hz220-240/1/50220-240/1/50
Heating(A7W35)CapacitykW8.3010.012.114.516.0
Rated inputkW1.602.002.443.093.56
COP5.205.004.954.704.50
Heating(A7W45)CapacitykW8.2010.012.314.216.0
Rated inputkW2.082.633.243.894.44
COP3.953.803.803.653.60
Heating(A7W55)CapacitykW7.509.5012.013.816.0
Rated inputkW2.363.063.874.605.52
COP3.183.103.103.002.90
Heating(A-7W35)CapacitykW7.18.25101213.3
Rated inputkW2.182.623.334.294.93
COP3.253.1532.82.7
Heating(A-7W55)CapacitykW6.156.85101112.5
Rated inputkW33.434.885.376.19
COP2.0522.052.052.02
Cooling(A35W18)CapacitykW8.4010.0012.0013.5014.2
Rated inputkW1.662.083.003.743.94
EER5.054.804.003.613.61
Cooling(A35W7)CapacitykW7.408.2011.612.714.0
Rated inputkW2.192.484.224.985.71
EER3.383.302.752.552.45
Seasonal space heating energy efficiency classLWT at 35⁰CA+++A+++A+++A+++A+++
LWT at 55⁰CA++A++A++A++A++
SCOPWarmer climate35⁰C6.997.096.486.586.29
55⁰C4.514.624.434.494.48
Average climate35⁰C5.225.204.814.724.62
55⁰C3.373.473.453.473.41
Colder climate35⁰C4.334.324.084.074.02
55⁰C2.882.993.023.053.12
SEERLWT at 7⁰C5.835.984.894.864.69
LWT at 18⁰C8.958.787.16.96.75
Rated water flowm3/h1.431.722.082.492.75
CompressorTypeTwin rotary DC inverter
Outdoor fanMotor typeBrushless DC motor
Number of fans11111
Air side heat exchangerTypeFinned tube
Refrigerant(R32)Factory chargekg1.651.651.841.841.84
Throttle typeElectronic expansion valve
Piping connectionsTypeFlare
Liquid Dia.(OD)mmΦ9.52Φ9.52Φ9.52Φ9.52Φ9.52
Gas Dia.(OD)mmΦ15.9Φ15.9Φ15.9Φ15.9Φ15.9
Min. pipe lengthm22222
Max. pipe lengthm3030303030
Installation height differenceOutdoor unit abovem2020202020
Outdoor unit belowm2020202020
Sound power leveldB5960646568
Sound pressure leveldB4649505154
Net dimensions (W×H×D)mm1118×865×5231118×865×5231118×865×5231118×865×5231118×865×523
Packed dimensions (W×H×D)mm1190×970×5601190×970×5601190×970×5601190×970×5601190×970×560
Net/Gross weightkg75/8975/8997/110.597/110.597/110.5
Operating temperature rangeCooling⁰C-5 to 43
Heating⁰C-25 to 35
DHW⁰C-25 to 43